From a2380956b02019058445c71a8707efbf4b3d5e10 Mon Sep 17 00:00:00 2001
From: zhangherong <571457620@qq.com>
Date: 星期五, 18 七月 2025 10:24:18 +0800
Subject: [PATCH] art: 数据库脚本、流程整理

---
 lxzn-module-eam/src/main/java/org/jeecg/modules/eam/controller/EamWeekInspectionDetailController.java |   21 ++++++++++++++++-----
 1 files changed, 16 insertions(+), 5 deletions(-)

diff --git a/lxzn-module-eam/src/main/java/org/jeecg/modules/eam/controller/EamWeekInspectionDetailController.java b/lxzn-module-eam/src/main/java/org/jeecg/modules/eam/controller/EamWeekInspectionDetailController.java
index 688836a..d98e0b9 100644
--- a/lxzn-module-eam/src/main/java/org/jeecg/modules/eam/controller/EamWeekInspectionDetailController.java
+++ b/lxzn-module-eam/src/main/java/org/jeecg/modules/eam/controller/EamWeekInspectionDetailController.java
@@ -6,15 +6,16 @@
 import lombok.extern.slf4j.Slf4j;
 import org.jeecg.common.api.vo.Result;
 import org.jeecg.common.system.base.controller.JeecgController;
-import org.jeecg.modules.eam.constant.InspectionItemCategroyEnum;
-import org.jeecg.modules.eam.entity.EamMaintenanceStandardDetail;
+import org.jeecg.common.util.StrUtils;
 import org.jeecg.modules.eam.entity.EamWeekInspectionDetail;
 import org.jeecg.modules.eam.service.IEamWeekInspectionDetailService;
 import org.jeecg.modules.eam.util.DateUtils;
 import org.springframework.web.bind.annotation.*;
 
 import javax.annotation.Resource;
+import java.util.HashMap;
 import java.util.List;
+import java.util.Map;
 
 /**
  * @Description: 鍛ㄧ偣妫�宸ュ崟鏄庣粏
@@ -39,13 +40,23 @@
      */
     @ApiOperation(value = "鍛ㄧ偣妫�宸ュ崟鏄庣粏-鏃ョ偣妫�瑙勮寖鍒楄〃鏌ヨ", notes = "鍛ㄧ偣妫�宸ュ崟鏄庣粏-鏃ョ偣妫�瑙勮寖鍒楄〃鏌ヨ")
     @GetMapping(value = "/queryStandardList")
-    public Result<?> queryStandardList(@RequestParam("standardId") String standardId) {
+    public Result<?> queryStandardList(@RequestParam("standardId") String standardId, @RequestParam("inspectionDate") String inspectionDate) {
         LambdaQueryWrapper<EamWeekInspectionDetail> queryWrapper = new LambdaQueryWrapper<>();
         queryWrapper.eq(EamWeekInspectionDetail::getStandardId, standardId);
-        queryWrapper.between(EamWeekInspectionDetail::getPlanInspectionDate, DateUtils.getFirstDayOfWeek(), DateUtils.getLastDayOfWeek());
+        queryWrapper.between(EamWeekInspectionDetail::getPlanInspectionDate, DateUtils.getFirstDayOfWeek(inspectionDate), DateUtils.getLastDayOfWeek(inspectionDate));
         queryWrapper.orderByAsc(EamWeekInspectionDetail::getItemCode);
         List<EamWeekInspectionDetail> list = eamWeekInspectionDetailService.list(queryWrapper);
-        return Result.OK(list);
+        //娣诲姞鐐规鍛ㄧ偣妫�鏄惁宸插畬鎴愭爣璇�
+        Map<String, Object> result = new HashMap<>();
+        result.put("list", list);
+        if (list != null && !list.isEmpty()) {
+            if (!StrUtils.isEmpty(list.get(0).getInspector())) {
+                result.put("weekInsFlag", true);
+            } else {
+                result.put("weekInsFlag", false);
+            }
+        }
+        return Result.OK(result);
     }
 
 }

--
Gitblit v1.9.3