From 042c5d8753bf8f7b1cb0b7d23400352989ba9915 Mon Sep 17 00:00:00 2001
From: zenglf <18502938215@163.com>
Date: 星期二, 10 十月 2023 00:25:12 +0800
Subject: [PATCH] application-test.yml 测试配置文件数据库地址修改

---
 lxzn-module-eam/src/main/java/org/jeecg/modules/eam/entity/PrecisionInspectionDetail.java |   36 ++++++++++--------------------------
 1 files changed, 10 insertions(+), 26 deletions(-)

diff --git a/lxzn-module-eam/src/main/java/org/jeecg/modules/eam/entity/PrecisionInspectionDetail.java b/lxzn-module-eam/src/main/java/org/jeecg/modules/eam/entity/PrecisionInspectionDetail.java
index fe90cfb..c413968 100644
--- a/lxzn-module-eam/src/main/java/org/jeecg/modules/eam/entity/PrecisionInspectionDetail.java
+++ b/lxzn-module-eam/src/main/java/org/jeecg/modules/eam/entity/PrecisionInspectionDetail.java
@@ -4,12 +4,12 @@
 import java.io.UnsupportedEncodingException;
 import java.util.Date;
 import java.math.BigDecimal;
-import com.baomidou.mybatisplus.annotation.IdType;
-import com.baomidou.mybatisplus.annotation.TableId;
-import com.baomidou.mybatisplus.annotation.TableName;
-import com.baomidou.mybatisplus.annotation.TableLogic;
+
+import com.baomidou.mybatisplus.annotation.*;
 import lombok.Data;
 import com.fasterxml.jackson.annotation.JsonFormat;
+import org.jeecg.common.constant.CommonConstant;
+import org.jeecg.common.system.base.entity.JeecgEntity;
 import org.springframework.format.annotation.DateTimeFormat;
 import org.jeecgframework.poi.excel.annotation.Excel;
 import org.jeecg.common.aspect.annotation.Dict;
@@ -29,13 +29,9 @@
 @Accessors(chain = true)
 @EqualsAndHashCode(callSuper = false)
 @ApiModel(value="mom_eam_precision_inspection_detail瀵硅薄", description="mom_eam_precision_inspection_detail")
-public class PrecisionInspectionDetail implements Serializable {
+public class PrecisionInspectionDetail extends JeecgEntity implements Serializable {
     private static final long serialVersionUID = 1L;
 
-	/**涓婚敭id*/
-	@TableId(type = IdType.ASSIGN_ID)
-    @ApiModelProperty(value = "涓婚敭id")
-    private String id;
 	/**绮惧害妫�楠岃〃id*/
 	@Excel(name = "绮惧害妫�楠岃〃id", width = 15)
     @ApiModelProperty(value = "绮惧害妫�楠岃〃id")
@@ -64,22 +60,7 @@
 	@Excel(name = "澶囨敞", width = 15)
     @ApiModelProperty(value = "澶囨敞")
     private String remark;
-	/**鍒涘缓浜�*/
-    @ApiModelProperty(value = "鍒涘缓浜�")
-    private String createBy;
-	/**鍒涘缓鏃堕棿*/
-	@JsonFormat(timezone = "GMT+8",pattern = "yyyy-MM-dd")
-    @DateTimeFormat(pattern="yyyy-MM-dd")
-    @ApiModelProperty(value = "鍒涘缓鏃堕棿")
-    private Date createTime;
-	/**鏇存柊浜�*/
-    @ApiModelProperty(value = "鏇存柊浜�")
-    private String updateBy;
-	/**鏇存柊鏃堕棿*/
-	@JsonFormat(timezone = "GMT+8",pattern = "yyyy-MM-dd")
-    @DateTimeFormat(pattern="yyyy-MM-dd")
-    @ApiModelProperty(value = "鏇存柊鏃堕棿")
-    private Date updateTime;
+
 	/**tenantId*/
 	@Excel(name = "tenantId", width = 15)
     @ApiModelProperty(value = "tenantId")
@@ -88,5 +69,8 @@
 	@Excel(name = "delFlag", width = 15)
     @ApiModelProperty(value = "delFlag")
     @TableLogic
-    private Integer delFlag;
+    private Integer delFlag = CommonConstant.DEL_FLAG_0;
+
+    @TableField(exist = false)
+    private String precisionParametersName;
 }

--
Gitblit v1.9.3