zhangherong
2025-07-11 4958e2592279bfb1dd3e3ee9ce39999cf461c832
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
package org.jeecg.modules.eam.controller;
 
import com.baomidou.mybatisplus.core.conditions.query.LambdaQueryWrapper;
import io.swagger.annotations.Api;
import io.swagger.annotations.ApiOperation;
import lombok.extern.slf4j.Slf4j;
import org.jeecg.common.api.vo.Result;
import org.jeecg.common.system.base.controller.JeecgController;
import org.jeecg.common.util.StrUtils;
import org.jeecg.modules.eam.entity.EamWeekInspectionDetail;
import org.jeecg.modules.eam.service.IEamWeekInspectionDetailService;
import org.jeecg.modules.eam.util.DateUtils;
import org.springframework.web.bind.annotation.*;
 
import javax.annotation.Resource;
import java.util.HashMap;
import java.util.List;
import java.util.Map;
 
/**
 * @Description: 周点检工单明细
 * @Author: jeecg-boot
 * @Date: 2025-04-02
 * @Version: V1.0
 */
@Api(tags = "周点检工单明细")
@RestController
@RequestMapping("/eam/eamWeekInspectionDetail")
@Slf4j
public class EamWeekInspectionDetailController extends JeecgController<EamWeekInspectionDetail, IEamWeekInspectionDetailService> {
 
    @Resource
    private IEamWeekInspectionDetailService eamWeekInspectionDetailService;
 
    /**
     * 周点检工单明细列表查询
     *
     * @param standardId
     * @return
     */
    @ApiOperation(value = "周点检工单明细-日点检规范列表查询", notes = "周点检工单明细-日点检规范列表查询")
    @GetMapping(value = "/queryStandardList")
    public Result<?> queryStandardList(@RequestParam("standardId") String standardId, @RequestParam("inspectionDate") String inspectionDate) {
        LambdaQueryWrapper<EamWeekInspectionDetail> queryWrapper = new LambdaQueryWrapper<>();
        queryWrapper.eq(EamWeekInspectionDetail::getStandardId, standardId);
        queryWrapper.between(EamWeekInspectionDetail::getPlanInspectionDate, DateUtils.getFirstDayOfWeek(inspectionDate), DateUtils.getLastDayOfWeek(inspectionDate));
        queryWrapper.orderByAsc(EamWeekInspectionDetail::getItemCode);
        List<EamWeekInspectionDetail> list = eamWeekInspectionDetailService.list(queryWrapper);
        //添加点检周点检是否已完成标识
        Map<String, Object> result = new HashMap<>();
        result.put("list", list);
        if (list != null && !list.isEmpty()) {
            if (!StrUtils.isEmpty(list.get(0).getInspector())) {
                result.put("weekInsFlag", true);
            } else {
                result.put("weekInsFlag", false);
            }
        }
        return Result.OK(result);
    }
 
}